Baxi E125 error code

E125 has appeared on your Baxi boiler. Here is what it means, what is safe to check, and when it is time to ring an engineer.

  • Gas Safe registered
  • Quote agreed in writing
  • Listed and period homes

Speak to us today

Mention the boiler make and whether the property is listed when you call.

01926 686642

Hours: Monday to Friday 7am to 7pm, Saturday 8am to 2pm, Sunday closed

Understanding E125

E125 means water is not circulating properly through your boiler. It may be preceded by E193, which Baxi says escalates to E125. Some causes are simple to rule out, others need a Qualified Gas Safe engineer.

Always cross-check with the manual for your exact model. We see this regularly in Hampton Magna, Coten End and Barford, as well as across Leamington and Kenilworth.

The usual culprits

Possible causes include:

  • Air in the system
  • Sludge or a blocked filter
  • A pump that is sticking or failing
  • Low pressure

When to book an engineer

Persistent E125 points to the pump or sludge.

Ring 01926 686642 with the code and your boiler's model, or use our enquiry form. We are open Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.

Try these first

1. Let trapped air out of the radiators

Air pockets interrupt the flow of water around the system. Once the heating has been off for a while, open the bleed screw on each radiator until a drop of water shows. Recheck the pressure when you have finished, as it will have dropped.

2. Start with the pressure

Once the system has cooled down, look at the pressure reading on your boiler. Most boilers want around 1 to 1.5 bar when cold, but your manual gives the figure for your model. If it reads under 1 bar, topping up is normally a homeowner job using the filling loop or filling key, which is more quite often than not underneath your boiler. Open the taps slowly, watch the needle rise, then close them firmly once you reach the right pressure. If it falls again soon after, water is escaping somewhere and that leak needs finding.

3. Reset your boiler once

Press the reset button as your manual describes: Baxi's reset steps depend on the model, so follow your user guide. Allow a little time for your boiler to try again. If the same code comes back, stop resetting: repeated resets can hide a fault that needs proper attention.

Never remove your boiler casing or touch the gas valve, gas pipes or flue. If there is a smell of gas, ring 0800 111 999 from outside.

Related error codes

Questions

What does Baxi E125 mean?

Water is not circulating properly. Bleed the radiators, look at the pressure and reset.

Do you repair Baxi boilers in Warwick?

We do. We work on Baxi boilers all over Warwick, from Hampton Magna to Myton. Call 01926 686642 with the code.

Boiler trouble in Warwick?

Call us and describe the problem; we'll arrange the right engineer.

Call usBook