Understanding EA 227
On a Worcester Bosch Greenstar, EA with cause code 227 is an ignition lockout: no flame was detected. Worcester's own guidance lists the gas supply, a frozen condensate pipe and a blocked flue outlet as things to check. Some causes are simple to rule out, others need a Qualified Gas Safe engineer.
Meanings vary a little between models; your manual has the definitive list. We see this regularly in Hatton Park, Warwick Gates and Barford, as well as across Leamington and Kenilworth.
The usual culprits
Possible causes include:
- A worn ignition or flame-sensing electrode
- Gas off or a prepayment meter with no credit
- A gas valve or PCB fault
- A blocked flue outlet
- A frozen or blocked condensate pipe
When to book an engineer
If the gas is on, the condensate is clear and EA 227 still returns, ring an engineer: which only a Qualified Gas Safe engineer should do.
Need a hand in Warwick? Call 01926 686642 or send us the details and we will call you back. Our hours are Monday to Friday 7am to 7pm and Saturday 8am to 2pm, closed on Sundays.
Try these first
1. Look at the gas supply
See whether another gas appliance, such as the hob, lights. Prepayment customers should look at the meter still has credit, as running out is a common cause of ignition lockouts. Nothing on the gas side of your boiler is a DIY job. If you smell gas, get everyone out and ring 0800 111 999.
2. Look at the condensate pipe outside
Every modern boiler has a small plastic condensate pipe, and outdoor sections freeze in a cold snap. A frozen pipe can make your boiler gurgle before it shuts down. As long as the pipe is low down and safe to reach, thaw it with warm water, never boiling, poured slowly along the pipe, then reset your boiler. Do not try this at height.
3. Glance at the flue terminal
Double-look at the flue terminal outside is not covered or blocked. Do not touch, remove or alter any part of the flue: if it looks damaged or blocked, switch your boiler off and ring an engineer.
4. Try a single reset
Follow the reset steps in your manual: on a Greenstar, hold it for around five seconds. Give it a few minutes to run through its start-up. If it locks out again, do not keep pressing: repeated resets can hide a fault that needs proper attention.
Never remove your boiler casing or touch the gas valve, gas pipes or flue. If you smell gas, leave the property and ring the National Gas Emergency Service on 0800 111 999.